船舶柴油机检验指南


获取其产品证书,查看其主要备件,测试其各种报警,检验其辅助设备和系统,

根据船舶建造日期和辅机功率,决定是否需要安装高压燃油管系的套管系统(JACKET PIPE SYSTEM)即套管/泄漏报警/集油盘/残油排放管连接到机舱污油舱等;

根据建造日期和辅机功率,决定是否需要主机大气防污染证书(EIAPP)。


Fuel Oil System(燃油系统)

Jacketed pipe system:1998年7月1日以前建造的船, 功率大于等于375千瓦的柴油机需安装; 小于375千瓦的需提供遮蔽装置, 若每个管路仅供给一个喷头, 尽管功率小于375千瓦, 也需安装套管系统. 1998年7月1日及以后建造的船, 无论柴油机的功率多大, 都需要安装套管系统,

艇机及应急消防泵除外.

对于无人机舱,无论缸径大小,高压燃油管系都应使用套管系统。

最新技术的发电机有种凸轮轴定时喷射装置,不需要高压燃油管系。


1 two fuel oil service tanks for each type of fuel used on board necessary for propulsion and vital systems or equivalent arrangements shall be provided on each new ship, with a capacity of at least 8 hours at maximum continuous rating of the propulsion plant and normal operationg load at sea of the generator p;ant. This paragraph applies only to shis constructed on or after 1 July 1998. (新造船应对推进及主系统必须的每一种燃油配备两个燃油柜或等效布置, 其容量必须至少能提供船舶推进装置在最大持续功率下, 以及发电机装置在海上正常负荷下工作8小时. 本节规定只适用于1998-7-1及以后建造的船

2 主推进装置及发电机组的原动机或锅炉用燃油,其闪点(闭杯)应不小于60度,应急发电机的原动机所用燃油的闪点可不低于43度。

3 2007年8月1日强制执行:燃油舱必须布置在船体的的双层舷侧板之内。(可将之横向地布置在货舱之间而达到要求)


Lube Oil System(滑油系统)

超过37KW的柴油机应安装滑油系统故障时的声光报警装置

1.若滑油循环舱延伸至外板,如滑油循环舱由隔离空舱与外板隔开,则不需要在油底壳和滑油循环舱之间的泄油管上装截止阀,反之需要。

2.所有船舶均应设置适当容量的滑油储存柜。

The condition and the quantity of lube oil pump and the condition of its pipe (滑油泵的数量及状况以及起管路状况)

1. 1台主滑油泵和1台独立动力的备用泵并应能供立即使用;重要用途的辅机,如每台都自带滑油泵,则不必设置备用泵,否则应设置备用泵。

2. 滑油管系应与其他管系分开,柴油机及齿轮箱不宜采用共同的滑油系统。

Lube oil separator(滑油分油机)无限航区船舶应装有滑油分油机,有限航区必要时也应装设Lube oil cooler (滑油冷却器)


Starting Air System(起动空气系统)/电起动装置

1. 至少2个空气瓶,不能换向的至少能使主机连续启动6次;能换向的至少启动12次。

2. 压缩机和空气瓶之间应设有油、气分离器,用以泄放压缩机排气中所含的油、气。

3. 电起动应设置2组独立的蓄电池组,且不应作并联连接。每一组都能起动主机,30min中内在不充电的情况下达到所要求的起动次数


SOLAS Chapter II-1-Part D-Reg. 41

1 this main source of electrical power shall consist of at least two generating sets. built on or after 1July 1986 (主电源至少应由两台发电机组成, 1986-7-1及以后建造者)

2 the arrangement of the main electric lighting system shall not render the emergency lighting system inoperative in any fire

or other casualty. Built on or after 1July 1986.

(主照明系统应布置成在任何火灾或其他事故时不致使应急照明系统失效, 反之亦然. 1986-7-1及以后建造者)

3 no electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers or in compartments assigned principally to accumulator batteries, in paint lockers, acetylene stores or similar spaces, unless the Administration is satisfied that such equipment is: (1) essential for operational purpose;(2) of a type which will not ignite the mixture concerned; (3) appropriate to the space concerned; and; (4) appropriately certified for safe usage in the dusts, vapours or gases likely to be encountered.

(电气设备不应安装在任何可燃混合气体易于积聚的处所内, 包括液货船上的此类处所或专门用来存放蓄电池的舱室, 油漆间, 乙炔贮藏室或类似处所, 除非主管机关确信这些设备是: (1) 操作所必须的; (2) 不会点燃有关的混合气体的型式; (3)适合于有关处所使用; 和 (4) 经证明在可能遇到的灰尘, 蒸汽或气体中安全使用.

4 Some of generator is not fitted with high pressure fuel oil pipe, so that it do not need fit with Jacketed Pipe System. 注意有些发电机并不需要高压燃油输油管线,所以不需要配备套管系统


本站仅提供存储服务,所有内容均由用户发布,如发现有害或侵权内容,请点击举报
打开APP,阅读全文并永久保存 查看更多类似文章
猜你喜欢
类似文章
【热】打开小程序,算一算2024你的财运
船舶柴油机你真的会管理吗?看看你中枪了几条!
【船机帮】船用柴油机高压油管安全保护装置及其故障一例
PSC迎检| 套管的事 撸透了!
聊聊柴油机高压燃油管的泄漏保护
【柴油机】船用柴油机高压燃油管路的安全保护及缺陷
三管轮面试须知的90个知识点
更多类似文章 >>
生活服务
热点新闻
分享 收藏 导长图 关注 下载文章
绑定账号成功
后续可登录账号畅享VIP特权!
如果VIP功能使用有故障,
可点击这里联系客服!

联系客服