打开APP
userphoto
未登录

开通VIP,畅享免费电子书等14项超值服

开通VIP
各厂家网络设备查看端口收发光功率

博猪很懒,半年都没写几篇像样的技术文章,今天抽风,汇总一下不同厂家设备的端口收发光命令吧,工程上经常用到,也经常容易忘记,备忘。

本文记录的设备型号有:cisco CRS、7609、Nexus7K、华为NE5000E、9312、8512、H3C 12508、中兴8905、Juniper EX8208、上海贝尔(阿尔卡特)OS10K、SR7750。

型号:思科CRS-1    系统版本:IOS XR , Version 4.0.4

CRS-1#show controllers SONET 0/0/1/0

  1. <…>
  2. Optical Power Monitoring (accuracy: +/- 1dB)
  3. Rx power = 0.0828 mW, -10.8 dBm
  4. Tx power = 1.0288 mW, 0.1 dBm
  5. Tx laser current bias = 68.3 mA
  6. !<---------POS口

 

CRS-1#show hw-module subslot 0/10/0 status pluggable-optics 0

  1. SPA 0/10/0 device pluggable-optics 0/0 info:
  2. int Tengige/10/0/0:
  3. State: Enabled
  4. Environmental Information - raw values
  5. Temperature: 8602
  6. Tx voltage: 0 in units of 100uVolt
  7. Tx bias: 63000 uA
  8. Tx power: 0 dBm (10180 in units of 0.1 uW)
  9. Rx power: -9 dBm (1126 in units of 0.1 uW)
  10. (AUX1) +3.3V Supply Voltage: 32324
  11. !<---------GE口

 

型号:思科7609

7609#show interfaces te1/1 transceiver

  1. Optical Optical
  2. Temperature Voltage Current Tx Power Rx Power
  3. Port (Celsius) (Volts) (mA) (dBm) (dBm)
  4. ---------- ----------- ------- -------- -------- --------
  5. Te1/1 40.3 N/A 83.6 -- 1.9 -14.3

 

型号:思科Nexus7010

N7K#show interface e3/1 transceiver details

  1. SFP Detail Diagnostics Information (internal calibration)
  2. ----------------------------------------------------------------------------
  3. Current Alarms Warnings
  4. Measurement High Low High Low
  5. ----------------------------------------------------------------------------
  6. Temperature 24.08 C 90.00 C -10.00 C 85.00 C -5.00 C
  7. Voltage 3.27 V 3.59 V 3.00 V 3.50 V 3.09 V
  8. Current 6.79 mA 15.00 mA 1.00 mA 12.00 mA 2.00 mA
  9. Tx Power 15.03 dBm 20.00 dBm 6.50 dBm 17.00 dBm 10.49 dBm
  10. Rx Power 12.35 dBm 23.00 dBm -1.02 dBm 20.00 dBm 3.01 dBm

型号:华为NE5000E

NE5000E#display interface pos 1/6/0/0

  1. <…>
  2. Rx Optical Power: -3.62dBm, Tx Optical Power: -2.25dBm
  3. Physical layer is Packet Over SDH
  4. Scramble enabled, clock master, CRC-32, loopback: none
  5. Flag J0 "NetEngine "
  6. Flag J1 "NetEngine "
  7. Flag C2 22(0x16)
  8. SDH alarm:
  9. section layer: none
  10. line layer: none
  11. path layer: none
  12. SDH error:
  13. section layer: B1 0
  14. line layer: B2 0 REI 0
  15. path layer: B3 0 REI 0
  16. <…>
  17. !<---------POS口

NE5000E#display interface gi1/8/0/1

  1. <..>
  2. WaveLength: 1310nm, Transmission Distance: 10km
  3. Rx Optical Power: -5.06dBm, Tx Optical Power: -2.01dBm
  4. Loopback:none, LAN full-duplex mode, Pause Flowcontrol:Receive Enable and Send Enable
  5. <..>
  6. !<-------GE口

 

型号:华为9312

S9312#display transceiver interface XGigabitEthernet 1/1/0/0 verbose

  1. <…>
  2. -------------------------------------------------------------
  3. Diagnostic information:
  4. Temperature(¡ãC) :35
  5. Voltage(V) :3.31
  6. Bias Current(mA) :6.52
  7. Bias High Threshold(mA) :10.00
  8. Bias Low Threshold(mA) :2.60
  9. Current Rx Power(dBM) :-3.12
  10. Default Rx Power High Threshold(dBM) :1.50
  11. Default Rx Power Low Threshold(dBM) :-14.00
  12. Current Tx Power(dBM) :-2.10
  13. Default Tx Power High Threshold(dBM) :-1.00
  14. Default Tx Power Low Threshold(dBM) :-8.00
  15. User Set Rx Power High Threshold(dBM) :1.50
  16. User Set Rx Power Low Threshold(dBM) :-14.00
  17. User Set Tx Power High Threshold(dBM) :-1.00
  18. User Set Tx Power Low Threshold(dBM) :-8.00
  19. -------------------------------------------------------------

 

型号:华为8512

S8512#display fiber-module GigabitEthernet 0/1/1

  1. GigabitEthernet0/1/1 transceiver information:
  2. Transceiver Type : 10G_LR_SM_LC
  3. Connector Type : LC
  4. Wavelength(nm) : 1310
  5. Transfer Distance : 10km(SMF)
  6. Digital Diagnostic Monitoring : YES
  7. Vendor Name : FINISAR CORP.
  8. TX Power : -2.0dBM
  9. RX Power : -2.5dBM

 

 

型号:H3C  12508

H3C12508#display transceiver diagnosis interface te3/0/1

  1. Ten-GigabitEthernet3/0/1 transceiver diagnostic information:
  2. Current diagnostic parameters:
  3. Temp.(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
  4. 30 3.36 30.10 -1.45 -2.01

 

型号:Juniper EX8208

EX8208>show interfaces diagnostics optics xe-0/0/1

  1. Physical interface: xe-0/0/1
  2. Laser bias current : 37.996 mA
  3. Laser output power : 0.6900 mW / -1.61 dBm
  4. Module temperature : 30 degrees C / 86 degrees F
  5. Module voltage : 3.2990 V
  6. Receiver signal average optical power : 0.5150 mW / -2.88 dBm
  7. <…>

 

型号:中兴8905     系统版本:V3.00.02.B10

ZXR10(config)#interface xgei-0/1/0/2

ZXR10(config-if)#optical-inform monitor enable

ZXR10#show optical-inform brief interface xgei-0/1/0/2

  1. If device is externally calibrated, only calibrated values are printed.
  2. -Inf: not applicable, Tx: transmit, Rx: receive.
  3. Optical Optical
  4. Interface Temperature Voltage Voltage Current Tx Power Rx Power
  5. Name (Celsius) (3.3 Volts)(5 Volts) (mA) (dBm) (dBm)
  6. --------------------------------------------------------------------------------
  7. xgei-0/1/0/2 33.20 3.27 N/A 54.01 1.87 -10.72

 

型号:上海贝尔Omniswitch 10K

OS10K>interfaces ddm enable

OS10K>show interfaces port 3/1 ddm

  1. Slot/ Thres- Temp Voltage Tx Bias Output Input
  2. Port hold (C) (V) (mA) (dBm) (dBm)
  3. ----------+--------+----------+------------+------------+------------+------------
  4. 3/1 Actual 21.0 3.258 4.136 -5.969 -6.719
  5. A-High 100.0 3.600 40.000 1.000 3.486
  6. W-High 90.0 3.500 30.000 0.000 2.486
  7. W-Low 0.0 3.100 1.000 -9.500 -12.518
  8. A-Low -5.0 3.000 0.500 -10.501 -13.516

 

型号:阿尔卡特(贝尔)SR 7750

SR7750#show port 1/1/1 detail | match DDM post-lines 10

  1. Last Cleared Time : 10/25/2012 15:54:54 DDM Events : Enabled
  2. Configured Mode : network Encap Type : null
  3. Dot1Q Ethertype : 0x8100 QinQ Ethertype : 0x8100
  4. PBB Ethertype : 0x88e7
  5. Ing. Pool % Rate : 100 Egr. Pool % Rate : 100
  6. Ing. Pool Policy : n/a
  7. Egr. Pool Policy : n/a
  8. Net. Egr. Queue Pol: default
  9. Egr. Sched. Pol : n/a
  10. Auto-negotiate : N/A MDI/MDX : N/A
  11. Transceiver Digital Diagnostic Monitoring (DDM)
  12. ===============================================================================
  13. Value High Alarm High Warn Low Warn Low Alarm
  14. -------------------------------------------------------------------------------
  15. Temperature (C) +28.8 +83.0 +80.0 -10.0 -13.0
  16. Tx Bias Current (mA) 37.9 80.0 75.0 20.0 15.0
  17. Tx Output Power (dBm) -1.97 1.50 1.00 -6.00 -7.00
  18. Rx Optical Power (avg dBm) -3.11 2.50 2.00 -18.01 -20.00
  19. Aux1: 3.3 Voltage (V) 3.29 3.63 3.50 3.10 3.00
  20. ===============================================================================
本站仅提供存储服务,所有内容均由用户发布,如发现有害或侵权内容,请点击举报
打开APP,阅读全文并永久保存 查看更多类似文章
猜你喜欢
类似文章
【热】打开小程序,算一算2024你的财运
设备光衰减查看 | 千月
5 tubes 20m SSB QRP transceiver
【新品推介】新款QRP收发信机丨JT65 / PSK / BPSK模式全搞定
linux系统下配置无线网卡的方法
CDMA 射频----APC(自动功率控制)与AGC(自动增益控制)
不同设备查看端口光功率命令
更多类似文章 >>
生活服务
热点新闻
分享 收藏 导长图 关注 下载文章
绑定账号成功
后续可登录账号畅享VIP特权!
如果VIP功能使用有故障,
可点击这里联系客服!

联系客服