单管支架在砖墙上安装
双管支架在砖墙上安装
管径(mm)类别滑动支架固定支架管径(mm)类别滑动支架固定支架规格间距
总重量(kg)总重量(kg)DN402.7
10m10m10m10mDN503
15保温4.7953.65815保温28.43926.891DN703.6
不保温1.8921.892不保温13.96413.964DN803.6
20保温3.613.30920保温21.66820.533DN1003.9
不保温1.5811.889不保温11.69511.695DN1254.2
25保温4.3684.18925保温22.95321.798DN1504.8
不保温1.731.73不保温10.77810.778DN2005.7
32保温5.3364.5632保温21.45920.535吨数0
不保温1.9921.922不保温11.02611.026
40保温4.7925.64440保温18.27221.255
不保温1.7152.009不保温9.8389.838
50保温5.1756.20450保温24.02623.031
不保温1.742.49不保温9.82412.058
70保温5.9887.69770保温20.07819.324
不保温2.1963.971不保温11.4411.44
80保温7.3669.24280保温30.08529.331
不保温2.4265.203不保温18.3318.33
100保温10.83715.554100保温36.44340.084
不保温3.98610.605不保温19.39319.393
125保温12.61722.721125保温38.81637.837
不保温5.62613.155不保温18.95918.959
150保温15.21422.898150保温38.45542.084
不保温7.03214.742不保温22.32324.825
水、煤气输送钢管规格、重量表
公称内径钢 管 螺 纹
外径 (mm)普通管加厚管
mm(in.)壁厚 (mm)理论重量 (不计管接头) (kg/m)壁厚 (mm)理论重量 (不计管接头) (kg/m)
61/8''1020.892.500.46
81/4''13.52.250.622.750.73
103/8''172.250.822.750.97
151/2''21.252.751.253.251.44
203/4''26.752.751.633.52.01
251''33.53.252.4242.91
321 1''/442.253.253.1343.77
401 1''/2483.53.844.254.58
502''603.54.884.56.16
702 1''/275.53.756.644.57.88
803''88.548.344.759.81
1004''114410.85513.44
1255''1404.515.045.518.24
1506''1654.517.815.521.63
注(1)表列钢管是适用于输送水、煤气及采暖系统等用的钢管。分镀锌和不镀锌(黑管)两种;又分带螺纹和不带螺纹两种;按壁厚可分为普通钢管,加厚钢管和薄壁钢管。
(2)钢管的长度规定为:无螺纹的黑管4~12m;带螺纹的黑管和镀锌管4~9m。每批允许有10%的(按根数计算)2~4m长的短尺钢管或4~9m米长的接管(即用一个管接头将两根钢管连接而成)。
(3)经供需双方协议,可供应定尺长度或倍尺长度的钢管。其最大长度可到8m。按倍尺交货的钢管,每个单倍尺应留切口5~10mm。
(4)钢管用易焊接的软钢制造,钢号和制造方法(炉焊或电焊)均由制造厂选择。
(5)钢管应能承受下列规定压力的水压试验:普通钢管和薄壁钢管:20kg/cm2;加厚钢管30kg/cm2。
钢材理论重量计算简式
材料名称 理论重量W(kg/m)
扁钢、钢板、钢带 W=0.00785×宽×厚
方钢 W=0.00785×边长2
圆钢、线材、钢丝 W=0.00617×直径2
钢管 W=0.02466×壁厚(外径--壁厚)
等边角钢 W=0.00785×边厚(2边宽--边厚)
不等边角钢 W=0.00785×边厚(长边宽+短边宽--边厚)
工字钢 W=0.00785×腰厚[高+f(腿宽-腰厚)]
槽钢 W=0.00785×腰厚[高+e(腿宽-腰厚)]
备注
1、角钢、工字钢和槽钢的准确计算公式很繁,表列简式用于计算近似值。
2、f值:一般型号及带a的为3.34,带b的为2.65,带c的为2.26。
3、e值:一般型号及带a的为3.26,带b的为2.44,带c的为2.24。
4、各长度单位均为毫米