2022东京备忘录CIC缺陷精选
2022东京备忘录
CIC缺陷精选


覃研深学   励精无怠

自9月1日开始,东京备忘录开展了为期三个月的以STCW为主题的集中检查会战CIC,截止到9月13日,共开展PSC检查782艘次,滞留21艘次。

其中澳大利亚、中国、印度尼西亚、日本,韩国、巴拿马、俄罗斯、泰国、越南均有滞留案例。

港口国监督研究分委会对上述滞留案例进行分类整理,选取17个典型缺陷,供行业参考。

案例 01
缺陷举例

02133 Asbestos containing materials

Objective evidence indicates the owners/managers failed to prevent new installation of Prohibited Asbestos Containing Materials (SOLAS II-1/3-5) on board vessel and maintain conditions of survey as required by SOLAS I/R11.

客观证据表明船东/管理公司违反SOLAS II-1/3-5的要求,在船上安装了石棉材料


案例 02
缺陷举例

18432 Risk evaluation, training and instruction to seafarers

Objective evidence indicates that the company failed to implement maintenance and monitoring programme with regards to ACMs on board; Company failed to make inventory and condition assessment of ACMs on board, failed maintain/implement Maintenance & Monitoring Programme, failed to take abatement actions, arrange planned repair and removal of ACMs.

客观证据表明公司没有按照ACM的要求开展石棉材料的管理

案例 03
缺陷举例

10109 Lights,shapes,sound-signals

Mast headlight used for stern light

桅灯被用作尾灯

案例 04
缺陷举例

02129 Bulkhead strength

At time of inspection found holes drilled for Air Conditioning unit on supersctructure (boat deck, crew deck and living deck)

PSCO检查期间发现,上层建筑部分舱壁由于安装空调被钻洞

案例 05
缺陷举例

01308 Records of rest

The records for hours of rest of 9 crew on Aug 2022 not available

自2022年8月开始,9名船员的劳动与休息时间记录不在船

案例 06
缺陷举例

03105 Covers (hatchway-, portable-, tarpaulins, etc.)

Part of cleats of No.1 cargo hold found unsecured during voyage

1号货舱部分舱盖锁紧装置故障

案例 07
缺陷举例

03108 Ventilators,air pipes,casings

Coming of ventilator for rope store room on forecastle deck holed

缆绳储存间通风筒围板锈蚀洞穿

案例 08
缺陷举例

07109 Fixed fire extinguishing installation

Fixed CO2 pipe to No.1 cargo hold rusted seriously

1号货舱CO2固定灭火管线锈蚀严重

案例 09
缺陷举例

07113 Fire pumps and its pipes

A large amount of fire hoses and hydrants on main deck leaking, one fire hydrant connection nearby No.5 cargo hold S/side holed, lack of fire hose in fire box nearby No.4 cargo hold

主甲板消防栓和消防皮漏水,5号货舱附近一消防栓洞穿,4号货舱附近一消防箱缺少皮

案例 10
缺陷举例

08109 Boiler alarm

Low level and low low level alarm of boiler water defective

锅炉低水位报警故障

案例 11
缺陷举例

07114 Remote Means of control (opening,pumps,ventilation,etc.)

 Machinery spaces Quick-closing valve for H.F.0 tank found leaking and inoperative during inspection

机舱燃油速闭阀泄漏,操作故障。

案例 12
缺陷举例

13101 Propulsion main engine

The ship presented a danger on 28th Aug 2022 that she unable to be maneuvered freely at CJK channel area of high density and narrow water due to M/E shut down which caused by crack of clamp on connection of exhaust gas collector

2022年8月28日,由于船舶主机故障,导致船舶在交通密集水域失控

案例 13
缺陷举例

11124 Embarkation arrangement survival craft

Davit-Launch Procedure for liferafts posted near the NO.2 embarkation station unreadable

救生筏登乘示意图不清晰

案例 14
缺陷举例

04121 Crew familiarisation with Emergency Systems

Duty engineer not familiar with the critical operation of valves and pipes system in the stage of fuel oil change over, it is demonstrated by the named vessel was unable to be maneuvered freely at CJK channel area, which is a high density and narrow water area, on 30th Aug 2022. The main engine shut down suddenly and presented a danger at that time, which was caused by the misused inlet valve of the intermediate shaft bearing lub. oil system, but not the valves in the fuel oil system.

值班轮机员不熟悉燃油转换系统重要阀门和管线的操作。事实上,2022年8月30日,该轮由于将燃油进口阀和中间轴滑油进口阀错误使用,导致主机停车,在密集水域失控。

案例15
缺陷举例

10127 Voyage or passage plan

The ship deviated from Baoshan channel to Wusong anchorage on Aug 30,no modification was made or recorded to the current voyage plan

该轮未在航行计划中记录 8月30日,从宝山偏离至吴淞锚地这一事实。

案例 16
缺陷举例

06101 Cargo Securing Manual

Lack of securing plan according to Cargo securing manual while vessel loading general cargo at this port

该轮装货期间,系统手册中缺少该批货物的系固计划。

案例 17
缺陷举例

14403 Sewage comminuting and disinfecting system

The current using chemical dosage for sewage treatment plant expired,temporary rubber pipe used for transferring treated sewage water from sewage treatment plant to holding tank via discharge connection on main deck ,unfortunately rubber pipe disconnect and sewage directly flow to main deck

生活污水处理装置药剂过期,临时连接软管断裂,导致生活污水溢流至主甲板。

以上仅代表作者本人观点

END

    供稿▕ 李伟

(东疆海事局蔡家堡海巡执法大队)

编辑▕ 韩畅

审核▕ 沈家强 王玲丽


船舶技术法规研究中心
本站仅提供存储服务,所有内容均由用户发布,如发现有害或侵权内容,请点击举报
打开APP,阅读全文并永久保存 查看更多类似文章
猜你喜欢
类似文章
【专题】东京备忘录航行安全集中大检查典型案例推送
今年的CIC大检查,怎么查? 海事局一个视频讲明白,棒!
【图文 视频】油轮、化学品船船舶结构
亚太地区PSC检查典型缺陷举例(2018年3月1日-4月30日)
近期CIC期间,PSCO滞留措施,分类汇编!
巴黎备忘录发布2017年航运安全CIC集中大检查结果
更多类似文章 >>
生活服务
热点新闻
分享 收藏 导长图 关注 下载文章
绑定账号成功
后续可登录账号畅享VIP特权!
如果VIP功能使用有故障,
可点击这里联系客服!

联系客服