Tx(℃) | Rmin(kΩ) | Rnom(kΩ) | Rmax(kΩ) |
-30.0 | 31.90 | 33.81 | 35.82 |
-29.0 | 30.09 | 31.85 | 33.70 |
-28.0 | 28.39 | 30.01 | 31.72 |
-27.0 | 26.79 | 28.29 | 29.87 |
-26.0 | 25.30 | 26.68 | 28.14 |
-25.0 | 23.89 | 25.17 | 26.51 |
-24.0 | 22.57 | 23.76 | 24.99 |
-23.0 | 21.33 | 22.43 | 23.57 |
-22.0 | 20.17 | 21.18 | 22.23 |
-21.0 | 19.07 | 20.01 | 20.97 |
-20.0 | 18.04 | 18.90 | 19.80 |
-19.0 | 17.08 | 17.87 | 18.69 |
-18.0 | 16.16 | 16.90 | 17.66 |
-17.0 | 15.31 | 15.98 | 16.68 |
-16.0 | 14.50 | 15.12 | 15.77 |
-15.0 | 13.74 | 14.31 | 14.90 |
-14.0 | 13.02 | 13.55 | 14.10 |
-13.0 | 12.34 | 12.83 | 13.33 |
-12.0 | 11.71 | 12.16 | 12.62 |
-11.0 | 11.11 | 11.52 | 11.94 |
-10.0 | 10.54 | 10.92 | 11.31 |
-9.0 | 10.00 | 10.36 | 10.71 |
-8.0 | 9.496 | 9.820 | 10.15 |
-7.0 | 9.019 | 9.316 | 9.619 |
-6.0 | 8.568 | 8.841 | 9.119 |
-5.0 | 8.141 | 8.392 | 8.647 |
-4.0 | 7.738 | 7.968 | 8.202 |
-3.0 | 7.357 | 7.568 | 7.782 |
-2.0 | 6.997 | 7.190 | 7.386 |
-1.0 | 6.656 | 6.833 | 7.011 |
0.0 | 6.333 | 6.495 | 6.658 |
Tx(℃) | Rmin(kΩ) | Rnom(kΩ) | Rmax(kΩ) |
1.0 | 6.028 | 6.175 | 6.324 |
2.0 | 5.378 | 5.873 | 6.008 |
3.0 | 5.464 | 5.587 | 5.710 |
4.0 | 5.205 | 5.316 | 5.428 |
5.0 | 4.959 | 5.060 | 5.161 |
6.0 | 4.717 | 4.818 | 4.919 |
7.0 | 4.488 | 4.589 | 4.690 |
8.0 | 4.272 | 4.372 | 4.472 |
9.0 | 4.067 | 4.167 | 4.256 |
10.0 | 3.874 | 3.972 | 4.071 |
11.0 | 3.690 | 3.788 | 3.886 |
12.0 | 3.517 | 3.613 | 3.710 |
13.0 | 3.352 | 3.447 | 3.543 |
14.0 | 3.197 | 3.290 | 3.385 |
15.0 | 3.049 | 3.141 | 3.234 |
16.0 | 2.909 | 2.999 | 3.091 |
17.0 | 2.776 | 2.865 | 2.956 |
18.0 | 2.650 | 2.737 | 2.827 |
19.0 | 2.530 | 2.616 | 2.704 |
20.0 | 2.417 | 2.501 | 2.587 |
21.0 | 2.309 | 2.391 | 2.476 |
22.0 | 2.206 | 2.287 | 2.370 |
23.0 | 2.109 | 2.188 | 2.270 |
24.0 | 2.016 | 2.094 | 2.174 |
25.0 | 1.929 | 2.005 | 2.083 |
26.0 | 1.845 | 1.919 | 1.996 |
27.0 | 1.765 | 1.838 | 1.913 |
28.0 | 1.690 | 1.761 | 1.834 |
29.0 | 1.618 | 1.687 | 1.759 |
30.0 | 1.549 | 1.617 | 1.687 |
代码 | 故障原因 | 重点检查 | 型号 |
E1 | 冷藏室感温头短路或断路 | 相应接插件和传感器回路 | 186A/E216A/E258B/E208/E 248W/E,195/E,205/E,262/E |
E2 | 冷冻室感温头短路或断路 | 相应接插件和传感器回路 | 248W/E |
E2 | 微冻室传感器短路或断路 | 相应接插件和传感器回路 | 258B/E,208/E |
E3 | 冷冻室感温头短路或断路 | 相应接插件和传感器回路 | 186A/E216A/E258B/E208/E 195/E、205/E、262/E |
E3 | 冷冻室化霜传感器短路或断路 | 相应接插件和传感器回路 | 248W/E |
E4 | 环温传感器短路或断路 | 相应接插件和传感器回路 | 208/E,195/E,205/E |
E4 | E2PROM出现读写故障 | 248W/E | |
E5 | 冷冻室超温报警 | 248W/E | |
E5 | E2PROM出现读写故障 | 186A/E216A/E258B/E208/E,262/E | |
E6 | 环温传感器短路或断路 | 相应接插件和传感器回路 | 248W/E |
E6 | 冷冻室温度持续过高 | 制冷剂泄漏 | 186A/E216A/E195/E205/E 262/E,265/E |
E7 | 通讯故障 | 接插件及线是否接错或断路 | 258B/E、195/E、205/E |
rS | 冷藏室传感器故障 | 212He212Hse192He192Hse | |
dS | 副蒸发器传感器故障 | 212He212Hse192He192Hse |
fS | 冷冻室传感器故障 | 212He212Hse192He192Hse |
eS | 外部传感器故障 | 212He212Hse192He192Hse |
L | 感温头温度过低或感温头温度偏移 | 186A/E218A/E258B/E208/E |
H | 感温头温度过高或感温头温度偏移 | 186A/E219A/E258B/E208/E |
DR | 开门报警 | 248W/E |